Advantages of Adjustable Type of MCCB
The load adjustable feature allows the MCCB to be fine-tuned to the actual load requirements of the electrical system. By adjusting the overload settings, the MCCB can cater to different levels of current flow without compromising its protective functions. This means that the MCCB can adapt to both normal variations in load and unexpected surges, providing consistent and reliable protection for the connected equipment.
Main performance index of WLM6RT series circuit breaker
WLM6RT Moulded Case Circuit Breaker |
630 | ||||||||||||
Rated operating current In (A),40℃ |
Thermal-magnetic type | 500-630 | |||||||||||
WLM6RT/Adjustable type | 500-630 | ||||||||||||
WLM6RT/A/Adjustable type Ir | 500-630 | ||||||||||||
WLM6RT/P/Adjustable type li | 500-630 | ||||||||||||
Electric characteristics | |||||||||||||
Rated insulation voltage Ui (V) | 1000 | ||||||||||||
Rated impulse withstand voltage (kV) | 8 | ||||||||||||
Rated operational voltage Ue(V),AC 50/60Hz | 380/400/415,440,500,660/690 | ||||||||||||
Breaking capacity code | S | M | H | Q | |||||||||
Number of poles | 1P(Adjutable has no this type) | - | - | - | - | ||||||||
2P | - | - | - | - | |||||||||
3P | - | ■ | ■ | ■ | |||||||||
4P | - | ■ | ■ | ■ | |||||||||
Number of poles | AC220/230/240V | - | 80 | 85 | - | ||||||||
AC380/400/415V | - | 70 | 100 | 150 | |||||||||
AC440V | - | - | - | - | |||||||||
AC500V | - | - | - | 65 | |||||||||
AC660/690V | - | 10 | 20 | 20 | |||||||||
Number of poles | AC220/230/240V | - | 30 | 50 | - | ||||||||
AC380/400/415V | - | 50 | 70 | 100 | |||||||||
AC440V | - | - | - | - | |||||||||
AC500V | - | - | - | 65 | |||||||||
AC660/690V | - | 10 | 12 | 20 | |||||||||
Standard | IEC/EN 60947-2 | ||||||||||||
Utilization category | A(Thermal-magnetic)/B(Electronic) | ||||||||||||
Ambient temperature | -40℃ ~+70 ℃ | ||||||||||||
Safety of insulation | ■ | ||||||||||||
Arcing distance | 0 | ||||||||||||
Mechanical life
(CO recycle)
|
Maintenance | 15000 | |||||||||||
Electrical life
(CO recycle)
|
AC415V,In | 8000 | |||||||||||
AC690V,In | 1500 | ||||||||||||
Release units | |||||||||||||
Distribution protection |
TM | ■ | |||||||||||
Motor protection |
TM | ■ | |||||||||||
Mounting and connection | |||||||||||||
Fixed |
Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
Plug-in |
Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
Draw-out | Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
DIN rail |
Front connection | - | |||||||||||
Dimension | |||||||||||||
Dimension (mm)
W×H×D
|
Width (1P/2P/3P/4P) | 140/184 | |||||||||||
Height | 257 | ||||||||||||
Depth | 103/111(Q TYPE) | ||||||||||||
Weight | |||||||||||||
Distribution protection |
1P | - | |||||||||||
2P | - | ||||||||||||
3P | 5.23/6(Q type) | ||||||||||||
4P | 6.809/7.3(Q type) |