Leave Your Message
Air circuit breaker WEW1-3200  acb withdrawable type acb  fixed type 400VAC/690VAC  3200A 3/4p acb

WEW1

Air circuit breaker WEW1-3200 acb withdrawable type acb fixed type 400VAC/690VAC 3200A 3/4p acb

Rated Current : 3200A

Number Of Poles : 3P/4P

Rated Working Voltage : 400V/690V

    Applications of 400V Air Circuit Breakers

    Data Centers: The uninterrupted operation of data centers is paramount, and 400V air circuit breakers are instrumental in providing reliable protection for the electrical systems that power these facilities. They help mitigate the risk of downtime and equipment damage, ensuring the continuous availability of critical IT infrastructure.

    Renewable Energy Installations: With the growing emphasis on renewable energy sources, 400V air circuit breakers are utilized in solar and wind power installations to protect the electrical components and ensure the efficient and safe operation of these systems.

    Infrastructure Projects: Whether it's in transportation, telecommunications, or utilities, 400V air circuit breakers are integral to the protection of electrical infrastructure in various public and private sector projects. They help maintain the reliability and safety of electrical systems that support essential services and operations.

    Main performance index of WEW1 series circuit breaker

    WEW1 Moulded Case Circuit Breaker
    3200
    Rated operating current In (A),40℃
    2000-2500-2900-3200-4000
    Rated insulation voltage Ui (V) 1000
    Rated impulse withstand voltage (kV) 12
    Rated operational voltage Ue(V),AC 50/60Hz 400V/690V
    Use category B
    Rated operational voltage Ue(V),AC 50/60Hz 100%In
    Breaking capacity code M H
    Number of poles
    3P
    4P
    Rated ultimate
    short-circuit breaking
    capacity Icu (kA)
    AC380V/400V/415V 100 100
    AC690V 65 65
    Rated service breaking
    capacity Ics (kA)
    AC220/230/240V 80 85
    AC380/400/415V 65 65
    Rated short-time withstand 
    current Icw (kA/1s)
    AC220/230/240V 80 85
    AC380/400/415V 65 65
    Mechanical life
    (CO recycle)
    Maintenance 20000
    Electrical life
    (CO recycle)
    AC415V,In 6000
    AC690V,In 2000
    Standard configuration Fixed Drawetry-pe
    The body of the circuit breaker
    Drawer base
    Intelligent controller
    Upper and lower horizontal connecting wires
    Indicating contact of opening/closing
    Indicating contact of fault tripping
    Auxiliary contact 4NO+4NC
    Electric motor operating mechanism
    Shunt releas
    Optional accessories
    Phase partition Fixed Drawetry-pe
    Instantaneous undervoltage release
    Time-delay undervoltage release
    Opening and closing button lock
    Lock for the drawer base
    Lock for the separation position of the drawer seat
    Key lock
    Door interlock
    Auxiliary contact 6NO+6NC
    Electric indications of three positions on the drawer base
    Steel cable interlock
    Locking interlock
    Dual power controller
    External neutral line transformer
    Zero-sequence transformer
    Ground current transformer and its accessories
    Dimension
    Dimension (mm)
    W×H×D
    Width (3P/4P) 57/66 61/66
    Height 55/60 58/60
    Depth 42/57 53/57
    Weight
    Weight(kg)/Fixed
    1P 66/69
    2P 90/92.5
    Weight(kg)/Drawer 3P 110/110.5
    4P 123/133

    Main performance index of WEW1 series circuit breaker

    3200 (1)vgu3200 (2)ada

    Door frame size and installation hole spacing

    3200Aa8h

    MCCB Production Line Real Showing