| Productes | Model | Actual | Polonesos | Descripció |
| Interruptor magnetotèrmic de 6 kA | JCB3-80M | 1A--80A | 1P, 2P, 3P, 4P | Corba B, C, D |
| JCB3-40M | 1A--40A | Corba B, C, D |
| JCB1-125 | 63A-125A | Corba C, D |
| Interruptor magnetotèrmic de 10 kA | JCB3-80H | 1A--80A | Corba B, C, D |
| JCBH-125 | 63A-125A | Corba C, D |
| Interruptor magnetotèrmic de 15 kA | JC3BE | 1A-80A | Corba B, C, D |
| MCB de CC | JCB3-63DC | 6A-63A | 250V, 500V, 750V, 1000V |
| JCB1-125DC | 63A-125A | 250V, 500V, 750V, 1000V |
| Aïllant | JCH2-125 | 16A-125A | / |
| JCMS100 | 16A-100A | / |
| JCMS125 | 16A-125A | / |
| RCD | JC3RH | 25A-100A | 2P, 4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S |
| JC3RH-S | 25A-100A | 2P, 4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S |
| JC3RH-B | 25A-100A | 2P, 4P | 30mA, 100mA, 300mA | Tipus B |
| RCBO | Electrònic | JCB2LE-40M | 2A-40A | 1P+N | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| JC3LFED | 2A-40A | 2P, 4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| JCB2LE-80M 2P | 6A-80A | 1P, 2P, 3P, 4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| JCB2LE-80M 4P | 6A-80A | 1P, 2P, 3P, 4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| JCB1LE-125 | 63A-125A | 2P, 4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| electromagnètic | JCB3LM-80 | 6A-80A | 2P/4P | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| JCR2-63 | 6A-63A | 1P+N | 30mA, 100mA, 300, 500mA | Tipus de CA, tipus A, A+S | Corba B, corba C |
| Tipus B | JC3LEB | 6A-63A | 2P, 4P | 30mA, 100mA, 300, 500mA | 2 no és, 4 no és | Corba B, corba C |
| AFDD | JC3AE | 6A-63A | 1 P, 2 P | 30mA, 100mA | Corba B, corba C |
| JC3AF-S | 6A-40A | 1 P, 2 P | 30mA, 100mA | Corba B, corba C |
| SPD de CA | JCSD-40 | Voltatge: 275V | 1 Cap, 2 Cap, 1P+N, 3 Cap, 4 Cap, 3P+N | Tipus 2 | 20kA/40KA |
| JCSP-40 | 1 Cap, 2 Cap, 1P+N, 3 Cap, 4 Cap, 3P+N |
| JCSD-60 | 2 pols, 1P+N, 4 pols, 3P+N | Tipus 2 | 30/60KA |
| JCSP-60 | (1000V 3P) |
| JCT1 | 2 pols, 1P+N, 4 pols, 3P+N | Tipus 1 | 12,5 kA/50 kA (10/350 µs) |
| Davantador de corrent continu | JCSPV | (per sota de 800V2P, per sobre de 1000V3P) | Tipus 2, 500 V CC, 600 V CC, 800 V CC, 1000 V CC, 1200 V CC, 1500 V CC |
| Contactor de CA | CJX2 | 3P, 4P | 9A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A |
| Caixa de distribució | Metall | MS, RCD, RCD dual | 4 vies, 6 vies, 8 vies, 10 vies, 12 vies, 14 vies, 16 vies, 18 vies, 20 vies, 22 vies, 28 vies, 36 vies |
| Plàstic | 4 vies, 8 vies, 12 vies, 18 vies, 26 vies, 36 vies, 54 vies |