| Produkter | Model | Strøm | Polakker | Beskrivelse |
| 6kA MCB | JCB3-80M | 1A--80A | 1P, 2P, 3P, 4P | B-, C-, D-kurve |
| JCB3-40M | 1A--40A | B-, C-, D-kurve |
| JCB1-125 | 63A-125A | C, D-kurve |
| 10kA MCB | JCB3-80H | 1A--80A | B-, C-, D-kurve |
| JCBH-125 | 63A-125A | C, D-kurve |
| 15kA MCB | JC3BE | 1A-80A | B-, C-, D-kurve |
| DC-automatsikring | JCB3-63DC | 6A-63A | 250V, 500V, 750V, 1000V |
| JCB1-125DC | 63A-125A | 250V, 500V, 750V, 1000V |
| Isolator | JCH2-125 | 16A-125A | / |
| JCMS100 | 16A-100A | / |
| JCMS125 | 16A-125A | / |
| RCD | JC3RH | 25A-100A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S |
| JC3RH-S | 25A-100A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S |
| JC3RH-B | 25A-100A | 2P, 4P | 30mA, 100mA, 300mA | B-type |
| Fejlstrømsafbryder | Elektronisk | JCB2LE-40M | 2A-40A | 1P+N | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| JC3LFED | 2A-40A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| JCB2LE-80M 2P | 6A-80A | 1P, 2P, 3P, 4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| JCB2LE-80M 4P | 6A-80A | 1P, 2P, 3P, 4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| JCB1LE-125 | 63A-125A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| Elektromagnetisk | JCB3LM-80 | 6A-80A | 2P/4P | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| JCR2-63 | 6A-63A | 1P+N | 30mA, 100mA, 300, 500mA | AC-type, A-type, A+S | B-kurve, C-kurve |
| B-type | JC3LEB | 6A-63A | 2P, 4P | 30mA, 100mA, 300, 500mA | 2 er ikke, 4 er ikke | B-kurve, C-kurve |
| AFDD | JC3AE | 6A-63A | 1 stk., 2 stk. | 30mA, 100mA | B-kurve, C-kurve |
| JC3AF-S | 6A-40A | 1 stk., 2 stk. | 30mA, 100mA | B-kurve, C-kurve |
| AC-hastighedsafbryder | JCSD-40 | Spænding: 275V | 1 Ingen, 2 Ingen, 1P+N, 3 Ingen, 4 Ingen, 3P+N | Type2 | 20kA/40KA |
| JCSP-40 | 1 Ingen, 2 Ingen, 1P+N, 3 Ingen, 4 Ingen, 3P+N |
| JCSD-60 | 2-polet, 1P+N, 4-polet, 3P+N | Type2 | 30/60KA |
| JCSP-60 | (1000V 3P) |
| JCT1 | 2-polet, 1P+N, 4-polet, 3P+N | Type1 | 12,5 kA/50 kA (10/350 µs) |
| DC-hastighedsafbryder | JCSPV | (under 800V2P, over 1000V3P) | Type 2, 500Vdc, 600Vdc, 800Vdc, 1000Vdc, 1200VdC, 1500Vdc |
| AC-kontaktor | CJX2 | 3P, 4P | 9A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A |
| Fordelingsboks | Metal | MS, RCD, dobbelt RCD | 4-vejs, 6-vejs, 8-vejs, 10-vejs, 12-vejs, 14-vejs, 16-vejs, 18-vejs, 20-vejs, 22-vejs, 28-vejs, 36-vejs |
| Plast | 4-vejs, 8-vejs, 12-vejs, 18-vejs, 26-vejs, 36-vejs, 54-vejs |