JC3LE-2P RCBO 2 Pole 6KA
Features
Electromagnetic Type
Residual current (rcd) protection
Earth Leakage protection
Overload and short circuit protection
Breaking capacity 6KA
Rated current up to 63A(available from 6A to 63A)
Available in B or C tripping curves
Type A or Type AC are avaible
Tripping sensitivity: 30mA,100mA,300mA
Connection from top or bottom are available
Neutral pole switching significantly reduces the installation and commissioning test time
Double handle (one control MCB, another control RCD)
Complies with IEC61009-1, EN61009-1
Application
The JC3LE-2P RCBO (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses
Technical Data
| Product code | JC3LE-2P | |
| Standard | IEC61009-1, EN61009-1 | |
| Electrical features | Rated current In (A) | 6, 10, 16, 20, 25, 32, 40, 63 |
| Type | Electronic | |
| Type(wave from of the earth leakage sensed) | A are available | |
| Poles | 2Pole | |
| Rated voltage Ue (V) | 230/240 | |
| Rated sensitivity IΔn | 30mA, 100mA, 300mA | |
| Insulation voltage Ui (V) | 500 | |
| Rated frequency | 50/60Hz | |
| Rated breaking capacity | 6KA | |
| Rated impulse withstand voltage (1.2/50) Uimp (V) | 6,000 | |
| Dielectric test voltage at ind.Freq. for 1 min (KV) | 2 | |
| Pollution degree | 2 | |
| Thermo-magnetic release characteristic | B, C | |
| Mechanical features | Electrical life | 2,000 |
| Mechanical life | 10,000 | |
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
| Reference temperature for setting of thermal element(℃) | 30 | |
| Ambient temperature(with daily average ≤35℃) | -5…+40 | |
| Storage temperature(℃) | -25…+70 | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable | 25mm2/18-3AWG | |
| Terminal size top/bottom for Busbar | 10mm2/18-8AWG | |
| Tightening torque | 2.5N*m/22In-lbs | |
| Mounting | On DIN rail EN 60715(35mm) | |
| Connection | From top or bottom are available | |

CSDM7-63H-3300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
JCB1-125
JCB2-40M
JCB3-80H
JCB3-80M
JC125-4P
JCB3-63DC
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCB2LE-80M
JCB2LE-80M
JCB1LE-125
JCB3LM-80
JCH2-125
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300 2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500