JC3LE-4P  4 Pole Electromagnetic RCBO
RCBO

JC3LE-4P 4 Pole Electromagnetic RCBO

Electromagnetic Type
Residual current (rcd) protection
Earth Leakage protection
Overload and short circuit protection
Breaking capacity 10KA
Rated current up to 63A(available from 6A to 63A)
Available in B or C tripping curves
Type A or Type AC are avaible
Tripping sensitivity: 30mA,100mA,300mA
Connection from top or bottom are available
Neutral pole switching significantly reduces the installation and commissioning test time
Double handle (one control MCB, another control RCD)
Complies with IEC61009-1, EN61009-1

    Features
    Electromagnetic Type
    Residual current (rcd) protection
    Earth Leakage protection
    Overload and short circuit protection
    Breaking capacity 10KA
    Rated current up to 63A(available from 6A to 63A)
    Available in B or C tripping curves
    Type A or Type AC are avaible
    Tripping sensitivity: 30mA,100mA,300mA
    Connection from top or bottom are available
    Neutral pole switching significantly reduces the installation and commissioning test time
    Double handle (one control MCB, another control RCD)
    Complies with IEC61009-1, EN61009-1

    Non Neutral Specific
    JC3LE-4P is a true 4 pole RCBO that offers unparalleled safety features for residential, commercial and industrial applications. Every pole can provide overload and short circuit protection. It can significantly reduce the risk of electric shock and equipment damage, safer and more reliable. You can choose any one pole as the Neutral according to your actual needs.

    Application
    The JC3LE-4P RCBO (residual current circuit breaker with overload protection) are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses

    Technical Data

      Standard IEC61009-1, EN61009-1
    Electrical features Rated current In (A) 6, 10, 16, 20, 25, 32, 40
    Type Electromagnetic
    Type(wave from of the earth leakage sensed) A are available
    Poles 4 Pole
    Rated voltage Ue (V) 400/415
    Rated sensitivity IΔn 30mA, 100mA, 300mA
    Insulation voltage Ui (V) 500
    Rated frequency 50/60Hz
    Rated breaking capacity 6KA
    Rated impulse withstand voltage (1.2/50) Uimp (V) 6,000
    Dielectric test voltage at ind.Freq. for 1 min (KV) 2
    Pollution degree 2
    Thermo-magnetic release characteristic B, C
    Mechanical features Electrical life 2,000
    Mechanical life 10,000
    Contact position indicator Yes
    Protection degree IP20
    Reference temperature for setting of thermal element() 30
    Ambient temperature(with daily average 35) -5+40
    Storage temperature() -25+70
    Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
    Terminal size top/bottom for cable 25mm2/18-3AWG
    Terminal size top/bottom for Busbar 10mm2/18-8AWG
    Tightening torque 2.5N*m/22In-lbs
    Mounting On DIN rail EN 60715(35mm)
    Connection From top or bottom are available

    MCCB Production Line Real Showing