Leave Your Message
JC3RS-B Residual Current Device
RCCB

JC3RS-B Residual Current Device

Electromagnetic Type
Earth Leakage Protection
Breaking capacity 6KA,10KA
Rated current up to 100A
Detect smooth DC residual currents
Tripping sensitivity: 30mA
Connection from top or bottom
Complies with IEC61008-1, IEC62423

    Features
    Electromagnetic Type
    Earth Leakage Protection
    Breaking capacity 6KA,10KA
    Rated current up to 100A
    Detect smooth DC residual currents
    Tripping sensitivity: 30mA
    Connection from top or bottom
    Complies with IEC61008-1, IEC62423

    B Type
    Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz,pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

    Application
    JC3RS-B Type B RCCBs are suitable for non-linear circuits that are able to generate leakage with high direct current(higher than 6mA)and/or high frequency components, for example single-phase rectifiers, rectifiers with active correction of the power factor, continuous voltage generator with no separation from AC networks and inverted at variable frequency.

      Standard IEC61008-1, EN61008-1
    Electronic features Rated current In (A) 25, 40, 50, 63, 80, 100
      Type Electromagnetic
      Type(wave form of the leakage sensed) AC, A, AC-G, A-G AC-S and A-S are available
      Poles 1P+N, 3P+N
      Rated voltage Ue (V) 1P+N: 230/240  3P+N: 400/415
      Rated sensitivity IΔn 30mA, 100mA, 300mA are available
      Insulation voltage Ui (V) 500
      Rated residual making and breaking capacity IΔm 500(In=25/40A), 630(In=63A), 1000(In=80/100A)
      Rated frequency 50/60Hz
      Rated breaking capacity 6KA, 10KA
      Rated impulse withstand voltage (1.2/50) Uimp (V) 6,000
      Dielectric test voltage at ind.Freq. for 1 min (KV) 2.5
      Pollution degree 2
    Mechanical features Electrical life 2,000
      Mechanical life 4,000
      Contact position indicator Yes
      Protection degree IP20
      Reference temperature for setting of thermal element() 30
      Ambient temperature(with daily average 35) -5+40
      Storage temperature() -25+70
    Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
      Terminal size top/bottom for cable 25mm2/18-3AWG
      Terminal size top/bottom for Busbar 10mm2/18-8AWG
      Tightening torque 2.5N*m/22In-lbs
      Mounting On DIN rail EN 60715(35mm)
      Connection From top or bottom are available

    MCCB Production Line Real Showing