Leave Your Message
JCH2-125 Main Switch Isolator 100A 125A

Lsolating Switch

JCH2-125 Main Switch Isolator 100A 125A

JCH2-125 series Main Switch is a switch disconnector which can be used as an Isolator, and can be used for residential and light commercial applications.
With plastic lock
With contact indicator
Rated current up to 125A
1 Pole, 2 Pole, 3 Pole , 4 Pole are available
Comply with IEC 60947-3

    Introduction

    JCH2-125 Main switch isolator is designed to employ the main switch that may simultaneously sever the connection between the live and neutral wires.
    JCH2-125 main switch that is also a switch disconnector which can be used as an Isolator, and can be used for residential and light commercial applications. The rate current is up to 125A. Rate current is available in 40A, 63A, 80A, 100A, 125A
    JCH2-125 Main switch is available in 1 pole, 2 pole, 3 pole and 4 Pole. The rated frequency is 50/60Hz. The rated impulse withstand voltage is 4000V. Rated short circuit withstand current lcw: 12le, t=0.1s. Rated making and breaking capacity: 3le, 1.05Ue, COSØ=0.65. IP20 rated.
    JCH2-125 Isolator has a green / red indication on the handle giving positive contact indication.Positive contact indicator: Green visible window indicates a 4mm contact gap.
    JCH2-125 Isolator is 35mm din rail mounted, easy for installation. It is compatible with Pin type / fork type standard busbars. It is Ideal for use where local isolation is required.
    JCH2-125 Isolator is a main switch only, without overload protection. It works to connect to cut off the load circuit.When it works as main switch, it may also trip when some of it's sub-circuit faulty. In such situation, it functions as main switch to function as earlier circuit protection.
    JCH2-125 Main switch isolator comply with IEC60947-3, EN60947-3


    Product Description

    wlo0x

    Main Features

    ● Rated current: 40A, 63A, 80A, 100A, 125A, providing a variety of options to adapt to various electrical load requirements.
    ● Usage type: AC-22A type, indicating the intended use of the isolating switch, that is, the type of load and duty cycle it can handle.
    ● Rated short circuit withstand current lcw: 12le, t=0.1s, ensuring robust protection and safety during short circuit.
    ● Rated short-circuit making capacity 1cm: 20le, t=0.1s, proving the ability of the isolating switch to handle short-circuit situations.
    ● Rated making and breaking capacity: 3le, 1.05Ue, COSØ=0.65, providing information on the making and breaking circuit performance of the isolating switch.
    ● Insulation voltage Ui: 690V, indicating the highest voltage at which the isolation switch can operate safely.
    ● Rated impulse withstand voltage Uimp: 4000V, ensuring reliable performance under impulse voltage conditions.
    ● IP rating: IP20 rating, providing protection against solid objects and limited protection against water.
    ● Current limiting level 3 indicates the ability of the isolating switch to limit the fault current.
    ● Contact position indicator red-green, provides visual indication of the contact position of the isolating switch to enhance safety and convenience.
    ● Available in 1-pole, 2-pole, 3-pole and 4-pole configurations to meet different installation requirements and electrical settings.
    ● Compatible with PIN or Fork type standard busbars, providing flexibility and compatibility with different busbar types.
    ● Ability to lock equipment in the "ON" or "OFF" position using an equipment lock or padlock, providing additional security and control over the operation of the disconnect switch.
    ● Comply with IEC60947-3 and EN60947-3 to ensure that electrical equipment complies with international standards and regulations, ensuring reliability and safety.

    Product code JCH2- 125
    Pole 1 Pole 2 Pole 3 Pole 4 Pole
      Standard IEC 60947-3 , EN 60947-3
     

    Electrical  features

    Rated  current  In   (A) 32 ,40 ,50 ,63 ,80 , 100 , 125
    Poles 1P , 2P , 3P , 4P
    Rated  voltage  Ue (V) 230/400~      240/415
    Insulation  voltage  Ui   (V) 500
    Rated  frequency 50/60Hz
    Rated impulse withstand voltage(1 .2/50) Uimp (V) 4000
    Rated short-time withstand current lcw 12le , 1s
    Rated making and breaking capacity  
    Rated short circuit making capacity 20le , t=0. 1s
    Dielectric test voltage at ind. Freq. for 5s 2kV
    Pollution degree 2
    Uilization category AC-22A
    Mechanicalfeatures Electrical  life 1500
    Mechanical  life 8500
    Contact  position  indicator Yes
    Protection  degree IP 20
    Reference  temperature  for  setting  of  thermal  element(℃) 30
    Ambient  temperature   (with  daily  average  ≤35℃) -5. . .+40 ℃
    Storage  temperation   (℃) -25...+70 ℃
    Installation Terminal  connection  type Cable/U-type  busbar/Pin-type  busbar
    Terminal  size  top/bottom  for  cable 50mm² / 18- 1/0 AWG
    Terminal  size  top/bottom  for busbar 35mm²   / 18-2  AWG
    Tightening  torque 2.5  N*m    /  22  In-Ibs.
    Mounting On  DIN  rail  EN  60715   (35mm)
    Connection From  top  and  bottom

    Technical Data

    ● Standards: IEC60947-3, EN60947-3, ensuring compliance with international standards for electrical equipment and ensuring reliability and safety.
    ● Rated current: 32A, 40A, 50A, 63A, 80A, 100A, 125A, providing a variety of options to adapt to various electrical load requirements.
    ● Number of poles: 1P, 2P, 3P, 4P to meet different installation requirements and electrical settings.
    ● Rated voltage Ue: 230V/400V~240V/415V, indicating the rated operating voltage range of the isolating switch.
    ● Insulation voltage Ui: 500V, ensuring safe operation under specified voltage conditions.
    ● Rated frequency: 50/60Hz, indicating the rated frequency of the isolating switch action.
    ● Rated impulse withstand voltage (1.2/50) Uimp: 4000V, ensuring reliable performance under impulse voltage conditions.
    ● Rated short-time withstand current lcw: 12le, 1s, providing strong protection and safety in the event of a short circuit.
    ● Rated making and breaking capacity: 3le, 1.05Ue, cosφ=0.65, providing information on the making and breaking circuit performance of the isolating switch.
    ● Rated short-circuit making capacity: 20le, t=0.1s, indicating the ability of the isolating switch to handle short-circuit situations.
    ● Insulation test voltage. frequency. Lasts 5 seconds: 2kV, ensuring electrical insulation and safety under specified test conditions.
    ● Pollution level: Level 2, indicating the degree of pollution that the isolation switch can withstand while maintaining safe and reliable operation.
    ● Mechanical life: 8500 times, indicating the number of mechanical operations that the isolation switch can withstand.
    ● Electrical life: 1500 times, indicating the number of electrical operations that the isolation switch can withstand.
    ● Protection level: IP20, providing protection against solid objects and limited waterproof protection.
    ● Ambient temperature (daily average ≤35℃): -5℃~+40℃, indicating the ambient temperature range in which the isolation switch can effectively operate.
    ● Contact position indicator: green = closed, red = open, provides visual indication of isolation switch contact position to enhance safety and convenience.
    ● Terminal connection method: Cable/Pin type busbar, flexible and compatible with different terminal connection methods.
    ● Installation method: Installed on DIN rail EN 60715 (35mm) through a quick clamp device, providing a standardized and convenient installation method.
    ● Recommended torque: 2.5Nm, ensure the isolation switch is installed and operated correctly.

    Standard  IEC/EN 60947-3

    Electrical features

    Rated current In (A) 32,40,50,63,80,100,125
    Poles 1P,  2P, 3P, 4P
    Rated voltage Ue(V) 230/400~240/415
    Insulation voltage Ui (V) 500
    Rated frequency 50/60Hz
    Rated impulse withstand voltage(1.2/50) Uimp (V) 4,000
    Rated short-time withstand current lcw 12le, 1s
    Rated making and breaking capacity 3le, 1.05Ue, cosφ=0.65
    Rated short circuit making capacity 20le, t=0.1s
    Dielectric test voltage at ind. Freq. for 5s 2kV
    Pollution degree 2
      Uilization category AC-22A

    Mechanical features

    Electrical life 1500
    Mechanical life 8500
    Contact position indicator Yes
    Protection degree IP20
    Ambient temperature (with daily average ≤35℃) -5…+40
    Storage temperation (℃) -25…+70
    Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
    Terminal size top/bottom for cable

    50mm2  / 18-1/0 AWG

    Terminal size top/bottom for Busbar

    35mm2  / 18-2 AWG

    Tightening torque

    2.5 N*m  /  22 In-Ibs.

    Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
    Connection From top and bottom
    JCH2-125-3n0q

     Q1: I wonder if you accept small orders?
     A1: Don't worry. Welcome to contact us. In order to accommodate different order sizes and provide customers with greater flexibility, we are happy to accept small orders and are committed to providing the same level of quality and service.

     Q2: Can you send the product to my country?
     A2: Of course, we can. If you don't have your own freight forwarder, we can help you arrange shipping to your country, ensuring a smooth and hassle-free shipping process.

     Q3: Can you do OEM for me?
     A3: We accept all OEM orders. Simply contact us with your design specifications and we will work closely with you to provide competitive pricing and produce samples in time for your approval.

     Q4: What are your payment terms?
     A4: We provide flexible payment terms, including T/T, L/C at sight, 30% deposit is required in advance, and the remaining 70% is paid against a copy of the bill of lading (B/L) to ensure a safe and transparent transaction process.

     Q5: How can I place an order?
     A5: To place an order, simply sign the Proforma Invoice (PI) and submit the required deposit. Once received, we will arrange production in time. Upon completion, we will provide you with a copy of the bill of lading for payment and upon receipt, ship the goods to you.

     Q6: When can I get the quotation?
     A6: We strive to provide timely and efficient service. Normally we aim to provide you with a quote within 24 hours of receiving your inquiry. If your request is urgent, please feel free to call us or indicate the urgency in your email and we will prioritize your inquiry accordingly.

    MCCB Production Line Real Showing