JCMS100 100A Main Switch Isolator
Product Detail
Main feature
Built-in plastic lock kit
With contact indicator
Rated current up to 100A
1 Pole, 2 Pole, 3 Pole, 4 Pole are available
Comply with IEC60947-3
| Standard | IEC/EN 60947-3 | |
|
Electrical features |
Rated current In (A) | 32,40,50,63,80,100,125 |
| Poles | 1P, 2P, 3P, 4P | |
| Rated voltage Ue(V) | 230/400~240/415 | |
| Insulation voltage Ui (V) | 500 | |
| Rated frequency | 50/60Hz | |
| Rated impulse withstand voltage(1.2/50) Uimp (V) | 4,000 | |
| Rated short-time withstand current lcw | 12le, 1s | |
| Rated making and breaking capacity | 3le, 1.05Ue, cosφ=0.65 | |
| Rated short circuit making capacity | 20le, t=0.1s | |
| Dielectric test voltage at ind. Freq. for 5s | 2kV | |
| Pollution degree | 2 | |
| Uilization category | AC-22A | |
|
Mechanical features |
Electrical life | 1500 |
| Mechanical life | 8500 | |
| Contact position indicator | Yes | |
| Protection degree | IP20 | |
| Ambient temperature (with daily average ≤35℃) | -5…+40 | |
| Storage temperation (℃) | -25…+70 | |
| Installation | Terminal connection type | Cable/U-type busbar/Pin-type busbar |
| Terminal size top/bottom for cable |
50mm2 / 18-1/0 AWG |
|
| Terminal size top/bottom for Busbar |
35mm2 / 18-2 AWG |
|
| Tightening torque |
2.5 N*m / 22 In-Ibs. |
|
| Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
| Connection | From top and bottom |
010203040506

CSDM7-63H-3300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
JCB1-125
JCB2-40M
JCB3-80H
JCB3-80M
JC125-4P
JCB3-63DC
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCB2LE-80M
JCB2LE-80M
JCB1LE-125
JCB3LM-80
JCH2-125
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300 2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500