Leave Your Message
JCB1LE-125 125A RCBO 6kA

RCBO

JCB1LE-125 125A RCBO 6kA

The JCB1LE-125 RCBOs (residual current circuit breaker with overload protection) are suitable for distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.
Electronic Type
Residual current protection
Overload and short circuit protection
Breaking capacity 6kA
Rated current up to 125A (available from 63A to 125A)
Available in B Curve or C tripping curves.
Tripping sensitivity: 30mA,100mA,300mA
Type A or Type AC are available
Complies with IEC 61009-1, EN61009-1
Available in B Curve or C tripping curves.
Tripping sensitivity: 30mA,100mA,300mA
Type A or Type AC are available
Complies with IEC 61009-1, EN61009-1

    Introduction

    The JCB1LE-125 RCBOs (residual current circuit breaker with overload protection) are suitable for distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

    They are suitable for AC 50Hz, single phase, 3 phase, rated current from 63A to 125A circuit.
    They prevent earth leakage, direct or indirect contact electric shock and other faults, and are applicable to low-voltage terminal power distribution in such fields as industry, civil construction, energy, communication and infrastructure. They provide short-circuit protection, overload protection, leakage protection and isolation protection.

    When personal electric shock or grid leakage, When the current exceeds the specified value, JCB1LE-125 RCBO will be quickly cut off the faulty power supply in a very short time to protect the safety of people and electrical equipment. At the same time, it can protect the line from overload or short-circuit, and it can also be used as an infrequent conversion of the line.

    Combination of ELCB & MCB (EL+MCB) offers 3 in 1 protection against -overload, short circuit and earth leakage

    Product Description

    1-24f4y

    Main Features
    ● Electronic type: JCB1LE-125 RCBO is designed with electronic components to ensure reliable and precise operation.
    ● Leakage protection: These RCBOs have the function of preventing leakage, which enhances the safety of the electrical system.
    ● Overload and short-circuit protection: RCBO provides comprehensive protection against overload and short-circuit conditions, protecting equipment and personnel.
    ● Non-Line/Load Sensitive: RCBO is designed to be insensitive to line/load conditions, ensuring consistent performance in a variety of electrical configurations.
    ● Breaking capacity: RCBO has a breaking capacity of up to 6kA, which can effectively break fault current and minimize potential damage to the electrical system.
    ● Rated current: Provides a variety of rated currents from 63A to 125A to meet different power load requirements.
    ● Trip curve: Type B and C trip curves are provided to provide flexible response characteristics for different applications.
    ● Trip sensitivity: RCBO offers 30mA, 100mA and 300mA trip sensitivity options for precise response to fault conditions.
    ● Type A or AC: Customers can choose between Type A or AC configurations to meet specific application needs.
    ● Insulating openings: RCBO has insulating openings to facilitate busbar installation and simplify the installation process.
    ● DIN rail installation: Designed for 35mm DIN rail installation, ensuring compatibility with standard mounting systems.
    ● Screwdriver compatibility: Compatible with a variety of combination head screwdrivers for easy installation and maintenance.
    ● Compliance: RCBO meets ESV additional testing and verification requirements to ensure compliance with industry standards for safety and performance. They also comply with IEC 61009-1 and EN61009-1 standards, providing quality and reliability assurance.

    Technical Data
    ● Standard: JCB1LE-125 RCBO complies with IEC 61009-1 and EN61009-1 standards to ensure compliance with industry safety and performance requirements.
    ● Type: This RCBO is electronic and uses advanced electronic components to work reliably and accurately.
    ● Type (detected leakage waveform): Customers can choose Type A or Type AC configurations to meet specific application needs, providing flexibility in leakage detection.
    ● Number of poles: Available in 1-pole, 2-pole, 3-pole and 4-pole configurations, suitable for various electrical system settings.
    ● Rated current: There are four rated currents: 63A, 80A, 100A, and 125A to meet different electrical load requirements.
    ● Rated working voltage: The rated working voltage of RCBO is AC 400V and 415V, ensuring compatibility with standard electrical systems.
    ● Rated sensitivity I△n: Provides 30mA, 100mA, and 300mA rated sensitivity options to accurately respond to fault conditions.
    ● Rated breaking capacity: The rated breaking capacity of RCBO is 6kA, which can effectively break fault current and minimize potential damage to the electrical system.
    ● Insulation voltage: RCBO insulation voltage is 500V, ensuring safe and reliable operation in various electrical environments.
    ● Rated frequency: The rated frequency is 50/60Hz, ensuring compatibility with standard power systems.
    ● Rated impulse withstand voltage (1.2/50): The rated impulse withstand voltage of RCBO is 6kV, which has strong protection against transient voltage surges.
    ● Pollution level: The pollution level is Level 2, suitable for use in moderately polluted environments.
    ● Thermal magnetic release characteristics: It has B-curve, C-curve and D-curve characteristics and can flexibly respond to overcurrent conditions.
    ● Mechanical life: The mechanical life is designed to be 10,000 times to ensure long-term reliability and durability.
    ● Electrical Life: These RCBOs have an electrical life of 2000 cycles, providing consistent performance over a long service life.
    ● Protection level: The protection level is IP20, which means it can protect solid objects larger than 12mm without harmful effects.
    ● Ambient temperature: Suitable for operation at ambient temperatures from -5°C to +40°C, with the daily average temperature not exceeding 35°C.
    ● Contact position indicator: Equipped with contact position indicator, green indicates OFF and red indicates ON, providing intuitive status indication.
    ● Terminal connection type: Compatible with cable or pin busbar connections, providing flexibility in installation options.
    ● Installation: Designed to be installed on DIN rail EN 60715 (35mm) using a quick clamp device to ensure simple and safe installation.
    ● Recommended torque: The recommended torque for terminal connection is 2.5Nm to ensure correct and firm connection.
    ● Connection method: Flexible connection from top or bottom for easy installation and maintenance.

    Standard

    IEC61009-1 ,  EN61009-1

    Electrical

    features

    Rated current In (A)

    63,80,100,125

    Type

    Electronic

    Type (wave form of the earth leakage sensed)

    A or AC are available

    Poles

    1 pole, 2 Pole, 3 pole, 4 pole

    Rated voltage Ue(V)

    230/240

    Rated sensitivity I△n

    30mA,100mA,300mA

    Insulation voltage Ui (V)

    500

    Rated frequency

    50/60Hz

    Rated breaking capacity

    6kA

    Rated impulse withstand voltage(1.2/50) Uimp (V)

    6000

    Pollution degree

    2

    Thermo-magnetic release characteristic

    B, C

    Mechanical

    features

    Electrical life

    2, 000

    Mechanical life

    2, 000

    Contact position indicator

    Yes

    Protection degree

    IP20

    Reference temperature for setting of thermal element(℃)

    30

    Ambient temperature (with daily average ≤35℃)

    -5...+40

    Storage temperation (℃)

    -25...+70

    Installation

    Terminal connection type

    Cable/Pin-type busbar

    Terminal size top/bottom for cable

    16~50/6-1/0 AWG

    Terminal size top/bottom for Busbar

    16~35mm2  / 6-2 AWG

    Tightening torque

    3.5 N*m  /  31 In-Ibs.

    Mounting

    On DIN rail EN 60715 (35mm) by means of fast clip device

    Connection

    From top or bottom are available

    2-23yzo

    JCB1LE-125 Dimensions

    JCB1LE-125-2ubu

    MCCB Production Line Real Showing

    Leave Your Message