Circuit Protection Products

HomeProductsCircuit Protection ProductsRCBORCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 1
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 2
  • RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole Gallery image 3

RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker JCB2LE-80M 2 Pole

The JCB2LE-80M 2 pole RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.

TECHNICAL DATA

JCB2LE-80M 6kA 2 Pole Electronic RCBO Specifications

The JCB2LE-80M 2 pole RCBO is listed by W9 Group for residual-current, overload and short-circuit protection. Confirm the selected current, waveform response and wiring arrangement on the matching datasheet.

Standard

IEC61009-1 ,  EN61009-1

Electrical

features

Rated current In (A)

6, 10, 16, 20, 25, 32, 40,50,63,80

Type

Electronic

Type (wave form of the earth leakage sensed)

A or AC are available

Poles

2 Pole

Rated voltage Ue(V)

230/240

Rated sensitivity I△n

30mA,100mA,300mA are available

Insulation voltage Ui (V)

500

Rated frequency

50/60Hz

Rated breaking capacity

6kA

Rated impulse withstand voltage(1.2/50) Uimp (V)

6000

Pollution degree

2

Thermo-magnetic release characteristic

B, C

Mechanical

features

Electrical life

2, 000

Mechanical life

10, 000

Contact position indicator

Yes

Protection degree

IP20

Reference temperature for setting of thermal element(℃)

30

Ambient temperature (with daily average ≤35℃)

-5…+40

Storage temperation (℃)

-25…+70

Installation

Terminal connection type

Cable/U-type busbar/Pin-type busbar

Terminal size top/bottom for cable

25mm2  / 18-3 AWG

Terminal size top/bottom for Busbar

10mm2  / 18-8 AWG

Tightening torque

2.5 N*m  /  22 In-Ibs.

Mounting

On DIN rail EN 60715 (35mm) by means of fast clip device

Connection

From top or bottom are available

SELECTION GUIDE

Selecting a Type A or AC 2 Pole RCBO for 6–80A Circuits

Specify the rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection when requesting a JCB2LE-80M quotation from W9 Group.

01

Select the rated current

The table lists 6, 10, 16, 20, 25, 32, 40, 50, 63 and 80 A. Specify the selected current rather than ordering only by series name.

02

Specify leakage protection

Choose Type A or Type AC and the required 30 mA, 100 mA or 300 mA sensitivity, subject to confirmation of the ordered combination.

03

Identify the breaking rating

Check the circuit’s prospective fault current against the standard 6 kA breaking capacity.

04

Check board connections

The table lists cable, U-type busbar and pin-type busbar terminals and top or bottom connection. Confirm compatibility with the board and follow the supplied installation instructions.

Before specifying JCB2LE-80M: Match rated current, trip curve, residual-current sensitivity and detection type to the circuit requirements. Use the wiring diagram for the selected configuration.

ABOUT W9 GROUP

W9 Group 2 Pole Electronic RCBO Supply and Support

Zhejiang W9 Group Technology Co., Ltd. includes RCBOs in its low-voltage electrical product range. For a JCB2LE-80M order, contact W9 Group about the required configuration and product documents.

W9 Group OEM and ODM circuit protection product scope
W9 Group circuit-protection range — category illustration.

RELATED RESOURCES

JCB2LE-80M 2 Pole Electronic RCBO Technical Document Requests

Use W9 Group’s RCBO guide and product directory for context. Request a datasheet and wiring diagram matching the selected JCB2LE-80M configuration.

BUYER FAQ

RCBO FAQs: Trip Curves and Leakage Sensitivity

Find answers about ratings, configuration and ordering.

Is JCB2LE-80M a 2 pole RCBO?

The JCB2LE-80M technical data lists two poles and live-and-neutral disconnection. Check terminal identification in the supplied wiring diagram.

Is the standard breaking capacity 6 kA or 10 kA?

The standard JCB2LE-80M rating is 6 kA. W9 Group also mentions a possible 10 kA upgrade; request the exact variant and its rating documents if your circuit requires the higher capacity.

Can I specify JCB2LE-80M as a 16 A RCBO?

The JCB2LE-80M current schedule includes 16 A, with B and C trip curves listed for the series. For a 16 A RCBO enquiry, specify the curve, residual-current sensitivity and Type A or Type AC detection. Confirm the exact combination on the quotation.

What is needed for a JCB2LE-80M quotation?

Send the required configuration, quantity and destination market. Ask W9 Group to confirm price, minimum order quantity and lead time for the selected model.

How should I specify JCB2LE-80M rated current and leakage sensitivity together?

State the load-current rating and residual-current sensitivity as separate selections, together with the waveform type and trip curve. Confirm the available JCB2LE-80M combination on the order-code datasheet.

What should I check for JCB2LE-80M cable or busbar connections?

Request the selected terminal drawing and confirm cable size, busbar form, tightening requirements and connection direction against the board design. Do not infer fit from the two-pole description alone.

Which JCB2LE-80M documents are needed for a consumer-unit layout?

Request the exact-version outline, connection diagram and operating instructions. Confirm the terminal clearance and board space for the selected JCB2LE-80M before installation.

PRODUCT ENQUIRY

Request a JCB2LE-80M 2 Pole Electronic RCBO Quotation

Tell W9 Group your rated current, breaking-capacity version, B or C curve, waveform type, residual-current sensitivity and terminal connection, quantity and destination market so the selected configuration can be identified.

Contact W9 Group