JCB2LE-80M 2 Pole RCBO Residual Current Circuit Breaker With Over Current and Leakage protection,Differential circuit breaker
Introduction
JCB2LE-80M RCBO (residual current circuit breaker with overload protection) provides protection against earth faults, overloads, short circuits. They are suitable for consumer units or distribution boards, applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.
JCB2LE-80M RCBO is more safe with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected.
JCB2LE-80M is a electronic type RCBO, which incorporates a filtering device preventing the risks of unwanted due to transient voltages and Transient currents.
JCB2LE-80M RCBOs feature dual pole switching with live and neutral disconnection. Available as Type AC (for alternating current only) or Type A (for alternating and pulsating DC currents)
JCB2LE-80M RCBO in 2 pole and 1P+N is a high-quality residual current circuit breaker and miniature circuit breaker combination with line voltage-dependent tripping and a wide variety of rated tripping currents. The built-in electronics precisely monitors where the currents flow. The difference between harmless and critical residual currents will be detected.
JCB2LE-80M RCBO provides indirect protection to the operator’s body under such a situation that the exposed live parts should be connected to a proper earth pole. It also provides overcurrent protection to circuits in the household, commercial, and other similar installations. Moreover, it prevents potential fire danger caused by earth fault current in case the overcurrent protection device fails.
JCB2LE-80M RCBO has a 6kA rating ideal for commercial and residential applications. The RCD/MCB combo will protect property and life should current be detected leaking to earth within 30mA. The switch has an inbuilt test switch and is easily reset after the fault is rectified.
Product Description
Standard |
IEC61009-1 , EN61009-1 |
|
Electrical features |
Rated current In (A) |
6, 10, 16, 20, 25, 32, 40,50,63,80 |
Type |
Electronic |
|
Type (wave form of the earth leakage sensed) |
A or AC are available |
|
Poles |
2 Pole |
|
Rated voltage Ue(V) |
230/240 |
|
Rated sensitivity I△n |
30mA,100mA,300mA are available |
|
Insulation voltage Ui (V) |
500 |
|
Rated frequency |
50/60Hz |
|
Rated breaking capacity |
6kA |
|
Rated impulse withstand voltage(1.2/50) Uimp (V) |
6000 |
|
Pollution degree |
2 |
|
Thermo-magnetic release characteristic |
B, C |
|
Mechanical features |
Electrical life |
2, 000 |
Mechanical life |
10, 000 |
|
Contact position indicator |
Yes |
|
Protection degree |
IP20 |
|
Reference temperature for setting of thermal element(℃) |
30 |
|
Ambient temperature (with daily average ≤35℃) |
-5...+40 |
|
Storage temperation (℃) |
-25...+70 |
|
Installation |
Terminal connection type |
Cable/U-type busbar/Pin-type busbar |
Terminal size top/bottom for cable |
25mm2 / 18-3 AWG |
|
Terminal size top/bottom for Busbar |
10mm2 / 18-8 AWG |
|
Tightening torque |
2.5 N*m / 22 In-Ibs. |
|
Mounting |
On DIN rail EN 60715 (35mm) by means of fast clip device |
|
Connection |
From top or bottom are available |