| Produkter | Modell | Aktuell | Polen | Beschreiwung |
| 6kA Automatesch Kontrollschalter | JCB3-80M | 1A--80A | 1P, 2P, 3P, 4P | B, C, D Kurve |
| JCB3-40M | 1A--40A | B, C, D Kurve |
| JCB1-125 | 63A-125A | C, D Kurve |
| 10kA Automatesch Kontrollschalter | JCB3-80H | 1A--80A | B, C, D Kurve |
| JCBH-125 | 63A-125A | C, D Kurve |
| 15kA Automatesch Kontrollschalter | JC3BE | 1A-80A | B, C, D Kurve |
| Gläichstroum-Automatik-Automatik (DC) | JCB3-63DC | 6A-63A | 250V, 500V, 750V, 1000V |
| JCB1-125DC | 63A-125A | 250V, 500V, 750V, 1000V |
| Isolator | JCH2-125 | 16A-125A | / |
| JCMS100 | 16A-100A | / |
| JCMS125 | 16A-125A | / |
| RCD | JC3RH | 25A-100A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S |
| JC3RH-S | 25A-100A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S |
| JC3RH-B | 25A-100A | 2P, 4P | 30mA, 100mA, 300mA | Typ B |
| RCBO | Elektronesch | JCB2LE-40M | 2A-40A | 1P+N | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| JC3LFED | 2A-40A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| JCB2LE-80M 2P | 6A-80A | 1P, 2P, 3P, 4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| JCB2LE-80M 4P | 6A-80A | 1P, 2P, 3P, 4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| JCB1LE-125 | 63A-125A | 2P, 4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| Elektromagnetesch | JCB3LM-80 | 6A-80A | 2P/4P | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| JCR2-63 | 6A-63A | 1P+N | 30mA, 100mA, 300, 500mA | AC-Typ, A-Typ, A+S | B-Kurve, C-Kurve |
| B-Typ | JC3LEB | 6A-63A | 2P, 4P | 30mA, 100mA, 300, 500mA | 2 ass net, 4 ass net | B-Kurve, C-Kurve |
| AFDD | JC3AE | 6A-63A | 1 P, 2 P | 30mA, 100mA | B-Kurve, C-Kurve |
| JC3AF-S | 6A-40A | 1 P, 2 P | 30mA, 100mA | B-Kurve, C-Kurve |
| AC SPD | JCSD-40 | Spannung: 275V | 1 Keen, 2 Keen, 1P+N, 3 Keen, 4 Keen, 3P+N | Typ2 | 20kA/40KA |
| JCSP-40 | 1 Keen, 2 Keen, 1P+N, 3 Keen, 4 Keen, 3P+N |
| JCSD-60 | 2-Polig, 1P+N, 4-Polig, 3P+N | Typ2 | 30/60KA |
| JCSP-60 | (1000V 3P) |
| JCT1 | 2-Polig, 1P+N, 4-Polig, 3P+N | Typ1 | 12,5 kA/50 kA (10/350 µs) |
| Gläichstroum-Spd | JCSPV | (ënner 800V2P, iwwer 1000V3P) | Typ 2, 500Vdc, 600Vdc, 800Vdc, 1000Vdc, 1200VdC, 1500Vdc |
| AC-Kontaktor | CJX2 | 3P, 4P | 9A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A |
| Verdeelerkëscht | Metall | MS, RCD, Duebel RCD | 4-Weeër, 6-Weeër, 8-Weeër, 10-Weeër, 12-Weeër, 14-Weeër, 16-Weeër, 18-Weeër, 20-Weeër, 22-Weeër, 28-Weeër, 36-Weeër |
| Plastik | 4-Weeër, 8-Weeër, 12-Weeër, 18-Weeër, 26-Weeër, 36-Weeër, 54-Weeër |