Advanced 4-Pole RCBO Enhances Electrical Safety
The JCB2LE-80M 4P RCBO (Residual Current Circuit Breaker with Overload Protection) represents a significant advancement in electrical safety technology. Designed to provide comprehensive protection against earth leakage, short circuits, and overloads, this four-pole device is engineered for reliability and performance in diverse electrical environments. With a breaking capacity of 6kA, it ensures robust interruption of fault currents, minimizing risks associated with electrical failures.
A key feature of this RCBO is its integrated contact indicator, which provides clear visual signaling of the device’s status. It offers tripping sensitivity options of 30mA, 100mA, and 300mA, making it suitable for a wide range of applications where residual current detection is critical. The inclusion of an alarm contact ensures automatic notification in the event of current leakage, enhancing preemptive safety measures.
Constructed as an electronic-type RCBO, it complies with the international standard IEC 61009-1 and EN61009-1, ensuring adherence to stringent safety and performance requirements. The device supports rated currents up to 80A, with available ratings from 6A to 80A, and offers both B and C tripping curves. Additionally, it is available in Type A or Type AC variants, providing flexibility for different electrical systems.
The JCB2LE-80M is recommended for use in consumer units and distribution boards across industrial, commercial, residential, and high-rise building applications. Its combination of high breaking capacity, adjustable sensitivity, and alarm functionality makes it an essential component in modern electrical protection systems. Installation torque is specified at 2.5 N·m to ensure secure and reliable operation.
By integrating multiple protective functions into a single unit, this RCBO simplifies electrical system design while improving safety and compliance. Its design emphasizes durability, precision, and user safety, aligning with the evolving demands of contemporary electrical infrastructures.


CSDM7-63H-3300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
JCB1-125
JCB2-40M
JCB3-80H
JCB3-80M
JC125-4P
JCB3-63DC
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCB2LE-80M
JCB2LE-80M
JCB1LE-125
JCB3LM-80
JCH2-125
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300 2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500