A significant advancement in electrical safety has arrived with the launch of the JCB2LE-80M, a two-pole RCBO (Residual Current Circuit Breaker with Overload Protection). This innovative device is engineered to offer a higher level of protection for both people and property, moving beyond the capabilities of traditional circuit breakers.
The core feature of this RCBO is its ability to provide complete isolation of a faulty circuit. Unlike some older models that might only interrupt the live wire, the JCB2LE-80M automatically switches off both the live and neutral conductors. This dual-pole switching is a critical safety function. It ensures that a circuit is entirely dead during a fault, maintenance, or inspection, significantly reducing the risk of electric shock for technicians and homeowners. This is particularly vital in situations where a fault could potentially energize the neutral wire.
This comprehensive protection covers several types of electrical hazards. The device guards against earth leakage, which can cause harmful electric shocks, and also provides standard overload and short-circuit protection to prevent damage to appliances and wiring that could lead to fires. With a high breaking capacity of 6kA—and options to upgrade to 10kA for certain models—it can reliably handle powerful electrical surges.
Flexibility is another key benefit. The RCBO is available in a wide range of configurations to suit various needs. Electricians can select from different rated currents (from 6A to 63A), tripping sensitivities (30mA for personal protection, 100mA or 300mA for fire prevention), and tripping curves (B or C) tailored to the type of connected equipment. Furthermore, it is available in both Type A and Type AC, making it compatible with a broader range of modern electrical devices, including those with electronic components that can cause smooth DC residual currents.
For electrical contractors, this device promises to streamline installations. The built-in switched neutral can reduce testing and commissioning time, making projects more efficient. Its design allows for top or bottom connection, offering greater versatility in how distribution boards are wired.
Suitable for everything from residential houses and high-rise apartments to commercial and industrial buildings, the JCB2LE-80M represents a move towards more robust and foolproof electrical safety standards. By ensuring a faulty circuit is completely disconnected from the power supply, it provides peace of mind that the electrical systems in our homes and workplaces are safer than ever before.


CSDM7-63H-3300
WLM6RT-125A
WLM6RT-160A
WLM6RT-250A
WLM6RT-400A
WLM6RT-630A
WLM6RT-800A
WLM6RT-1250A
JCB1-125
JCB2-40M
JCB3-80H
JCB3-80M
JC125-4P
JCB3-63DC
JCMX
JCSD
JCOF
JCMX1-125
JCOF1-125
JCSD1-125
JCR3HM
JCRD2-125
JCRD4-125
JCRB2-100
JC3RH-2P
JC3RH-S
JC3RH-B
JC3RH-BS
JCR2-63
JCB2LE-80M
JCB2LE-80M
JCB1LE-125
JCB3LM-80
JCH2-125
CJ19
JCMCU
JCHA
JCSD-40
JCSD-60
JCSP-40
JCSP-60
JCSPV
WEW1-1000
WEW1-1600
WEW1-2000
WEW1-3200
WEW1-4000
WEW1-6300
DC6-125
AX-400-1250
AXAL-400-1250A
AL-400-1250
DC3-160
AXS-400-1250A
SHT-125-160
UVT-125-160A
P-250A-3P-A
400-3P/4P terminal cover
1250-3Pmccb accessories busbar
250-3P terminal conver
WLM6-TCV-160A-3P
WLM6-MIP-250A
WLM6-125A-3300 3P/4P
WLM6-160A-3300 3P/4P
WLM6-250A-3300 3P/4P
WLM6-400A-3300 3P/4P
WLM6-630A-3300 3P/4P
WLM6-800A-3300 3P/4P
WLM6-1250A-3300 3P/4P
WLM6-1600A-3300 3P/4P
WLM6-2000A 3P/4P
WLM8-125H-3300
WLM8-250H-3300
WLM8-400H-3300
WLM8-400H-4300
WLM8-630H-3300
WLM8-630H-4300
WLM6E-160A-3300 3P
WLM6E-250A-3300
WLM6E-400A-3300 3P/4P
WLM6E-630A-3300
WLM6E-800A-3300 3P/4P
WLM6E-1250A-3300
WLM6E-1600-3300 3P/4P
WLM6E-2000A-3300 3P/4P
WLM8E-250H-3300
WLM8E-400H-3300
WLM8E-400H-4300
WLM8E-630H-3300
WLM8E-630H-4300
WLM6EY-250-3300 3P/4P
WLM6EY-400 3P/4P
WLM6EY-630 3P/4P
WLM6EY-800A 3P/4P
WLM6EY-1250A 3P/4P
WLM6ELY-160A
WLM6ELY-250A
WLM6ELY-400A
WLM6ELY-800A
WLM8EY-250H-3300
WLM8EY-400H-3300
WLM8EY-630H-3300
WLM6LY-125A
WLM6L-160A
WLM6LY-250A
WLM6LY-400A
WLM6LY-800A
WLM6LY-630A
WLM6LY-1250A
WLM8LY-125H-3300
WLM8LY-250H-3300
WLM8LY-400H-3300
WLM8LY-630H-3300
WLM7DC-250A-2300 2P/3P
WLM7DC-315A-3300 2P/3P
WLM7DC-400A-2300 2P/3P
WLM7DC-630A-3300 3P
WLM7DC-800A-2300 2P/3P
WLM7DC-400A 2300
WLM7DC-630A-2300 2P
WLM7HU-250-3300 3P
WLM7HU-315-3300 3P
WLM7HU-400-3300 3P
WLM7HU-630-3300 3P
WLM7HU-800-3300 3P
PV-1500V/250A
WEW3-1600
WEW3-2500
WEW3-4000
WEW3-7500