Rated Current : 630A

Number Of Poles : 3P

Rated Working Voltage : 800V

    MCCB Highlights

    1. Advanced and safe arc extinguishing system structure design;
    2. Zero flashover can be achieved by installing the protective cover. Double insulation: pole to pole connection and complete isolation of main circuit;
    The products are widely used in the field of new energy. AC MCCB: series inverter application (power station type): PV string is inverted by inverter DC/AC, and the output AC is boosted and connected to the grid after being converged by AC combiner box. AC combiner box and low-voltage side of box substation shall be equipped with AC circuit breaker, with working voltage of AC900V → AC1140V. The operating voltage of direct grid connection mode is relatively low, generally less than AC400V.


    Main performance index of WLM7HU series circuit breaker

    WLM7HU Moulded Case Circuit Breaker
    630
    Rated operating current In (A),40℃
    400-500-630
    Rated insulation voltage Ui (V) 1250
    Rated impulse withstand voltage (kV) 12
    Rated operational voltage Ue(V),AC 50/60Hz
    415/690/800/1000/1140v
    Breaking capacity code - M H
    Number of poles 3P
    -
    AC415V - - 100
    AC690V - 60 65
    Rated ultimate
    short-circuit breaking
    capacity Icu(kA)
    AC800V - 50 50
    AC1000V - 20 30
    AC1140V - 15 20
    AC415V - - 100
    AC690V - 60 65
    Rated service breaking
    capacity Ics(kA)
    AC800V - 37.5 50
    AC1000V - 20 30
    AC1140V - 15 20
    Standard
    Utilization category
    Ambient temperature
    Safety of insulation
    Arcing distance
    Mechanical life
    (CO recycle)
    Maintenance free 15000
    Electrical life
    (CO recycle)
    Maintenance free 1000-5000
    Release units
    Distribution protection
    TM
    Mounting and connection
    Fixed
    Front connection
    Rear connection
    Plug-in
    Front connection
    Rear connection
    Draw-out
    Front connection -
    Rear connection -
    DIN rail
    Front connection -
    Dimension
    Dimension (mm)
    W×H×D
    Width 182
    Height 270
    Depth 125.8
    Weight
    Weight(kg)/Fixed
    3P 8

    Overall and installation dimensions of circuit breaker