WLM7HU-315-3300 3P Photovoltaic solar mccb molded case circuit breaker 800V mccb 800VAC/1000VAC/1140VAC mccb315A mccb
MCCB Highlights
800V MCCBs for isolator application offer solution for switching various loads such as UPS,battery banks,etc.with many advantages.These MCCBs differ from regular MCCBs only in terms of absence of protection trip units.These MCCBs can be used for following applications for isolation purpose:
·For local isolation:such as very close to motor load
·Incoming of any sub-distribution
·As an isolator for bus coupler
·As an automatic switch
·For switching applications of motors with VFDs,soft starters
lsolator application MCCBs are always backed up by short circuit protection device to protectthe downstream loads/installations against short circuit.Following advantages are offered byisolator MCCBs:
·Suitable for positive isolation
·Available with 3P and 4P versions
·Can be used with under voltage protection
·Remote tripping through shunt release
·Motor operated MCCBs
·Status Feedback possible
Main performance index of WLM7HU series circuit breaker
WLM7HU Moulded Case Circuit Breaker |
315 | ||||||||||||
Rated operating current In (A),40℃ |
280-300-315 | ||||||||||||
Rated insulation voltage Ui (V) | 1150 | ||||||||||||
Rated impulse withstand voltage (kV) | 12 | ||||||||||||
Rated operational voltage Ue(V),AC 50/60Hz | 415/690/800/1000/1140v
|
||||||||||||
Breaking capacity code | - | M | H | ||||||||||
Number of poles |
3P |
- | ■ | ■ | |||||||||
AC415V | - | - | - | ||||||||||
AC690V | - | - | - | ||||||||||
Rated ultimate
short-circuit breaking
capacity Icu(kA)
|
AC800V | - | 35 | 50 | |||||||||
AC1000V | - | 15 | 20 | ||||||||||
AC1140V | - | 15 | 15 | ||||||||||
AC415V | - | - | - | ||||||||||
AC690V | - | - | - | ||||||||||
Rated service breaking
capacity Ics(kA)
|
AC800V | - | 35 | 50 | |||||||||
AC1000V | - | 15 | 20 | ||||||||||
AC1140V | - | 15 | 15 | ||||||||||
Standard | IEC/EN 60947-2 | ||||||||||||
Utilization category | A | ||||||||||||
Ambient temperature | -40℃ ~+70 ℃ | ||||||||||||
Safety of insulation | ■ | ||||||||||||
Arcing distance | 0 | ||||||||||||
Mechanical life
(CO recycle)
|
Maintenance free | 20000 | |||||||||||
Electrical life
(CO recycle)
|
Maintenance free | 1500 | |||||||||||
Release units | |||||||||||||
Distribution protection |
TM | ■ | |||||||||||
Mounting and connection | |||||||||||||
Fixed |
Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
Plug-in |
Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
Draw-out | Front connection | - | |||||||||||
Rear connection | - | ||||||||||||
DIN rail |
Front connection | - | |||||||||||
Dimension | |||||||||||||
Dimension (mm)
W×H×D
|
Width | 107 | |||||||||||
Height | 200 | ||||||||||||
Depth | 109 | ||||||||||||
Weight | |||||||||||||
Weight(kg)/Fixed |
3P | 3 |
Overall and installation dimensions of circuit breaker