WLM6ELY-250A-4300 3P WLM6E Series electronic circuit breaker lsig circuit breaker MCCB 250A 4 Poles
Residual Current Circuit Breaker with Liquid Crystal Display (RCCB with LCD Type): Functions and Benefits
Real-time Monitoring: The LCD display provides real-time monitoring of electrical parameters, including current, voltage, and residual current. This allows users to track the status of the electrical system and identify any abnormalities or faults.
Fault Indication: The LCD display is equipped to indicate various types of faults, such as earth leakage, overcurrent, and short circuits. This feature enables prompt identification and troubleshooting of electrical faults, minimizing downtime and ensuring continuous operation.
Main performance index of WLM6LEY series circuit breaker
WLM6LEY Moulded Case Circuit Breaker |
250 | ||||||||||||
Rated current (A) of circuit breaker 40℃ |
Fix type |
100-125-140-150-160
175-180-200-225-250
|
|||||||||||
Lcd type |
100-125-140-150-160
175-180-200-225-250
|
||||||||||||
Rated insulation voltage Ui (V) | 1000 | ||||||||||||
Rated impulse withstand voltage (kV) | 8 | ||||||||||||
Rated operational voltage Ue(V),AC 50/60Hz | AC400V | ||||||||||||
Breaking capacity code | C | S | M | H | |||||||||
Number of poles | 2P | - | - | - | - | ||||||||
3P | - | - | ■ | ■ | |||||||||
4P | - | - | ■ | ■ | |||||||||
Rated ultimate
short-circuit breaking
capacity Icu (kA)
|
AC380/400/415V | 15 | 25 | 35 | 50 | ||||||||
AC380/400/415V | 10 | 18 | 25 | 35 | |||||||||
Rated residual making and breaking capacity
I△ m(kA)
|
AC220/230/240V | - | - | 12.5 | 12.5 | ||||||||
Limit non-actuating time △ t (ms) | 0.06s/0.2s/0.5s/1s | ||||||||||||
Leakage alarm non-tripping function | □ | ||||||||||||
overcurrent tripping type | Themal type | ||||||||||||
Leakage tripping type | Electronic Type | ||||||||||||
Residual current type | AC | ||||||||||||
Standard | IEC/EN 60947-2 | ||||||||||||
Utilization category | A | ||||||||||||
Ambient temperature | -40℃ ~+70 ℃ | ||||||||||||
Safety of insulation | ■ | ||||||||||||
Arcing distance | 0 | ||||||||||||
Mechanical life
(CO recycle)
|
Maintenance | 15000 | |||||||||||
Electrical life
(CO recycle)
|
AC415V,In | 8000 | |||||||||||
AC690V,In | 2000 | ||||||||||||
Release units | |||||||||||||
Mounting and connection | |||||||||||||
Fixed |
Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
Plug-in |
Front connection | ■ | |||||||||||
Rear connection | ■ | ||||||||||||
Draw-out | Front connection | - | |||||||||||
Rear connection | - | ||||||||||||
DIN rail |
Front connection | ■ | |||||||||||
Dimension | |||||||||||||
Dimension (mm)
W×H×D
|
Width (2P/3P/4P) | -/105/140 | |||||||||||
Height | 165 | ||||||||||||
Depth | 68 | ||||||||||||
Weight | |||||||||||||
Distribution protection |
2P | - | |||||||||||
3P | 1.532 | ||||||||||||
4P | 2.024 |
Electronic tripper | Frame rated current Inm(A | Rated curren ) In(A) | t Setting current of adjustable overload release IR(A) | Tripping characteristic/time |
Overload long-time delay | 125 | 32 | 12.5-14-16-18-20-22-25-28-30-32 | 1.05In non tripping time (≥ 2 hours, In>63A;); 1.30 In trip time (<2 hours, In>63A); |
63 | 25-28-32-36-40-45-50-56-60-63 | |||
125 | 50-56-63-70-75-80-90-100-110-125 | |||
160 | 63 | 25-28-32-36-40-45-50-56-60-63 | ||
125 | 50-56-63-70-75-80-90-100-110-125 | |||
160 | 63-70-80-90-100-110-125-140-150-160 | |||
250 | 250 | 100-110-125-140-150-160-180-200-225-250 | ||
320 | 320 | 125-140-160-180-200-225-250-280-300-320 | ||
400 | 400 | 160-180-200-225-250-280-315-350-375-400 | ||
630 | 630 | 250-280-315-350-375-400-450-500-560-630 | ||
800 | 630 | 250-280-315-350-375-400-450-500-560-630 | ||
800 | 315-350-400-450-500-560-630-700-760-800 | |||
1250 | 1250 | 500-630-700-800-850-900-950-1050-1150-1250 | ||
1250 Custom- made | 1000 | 630-680-700-750-800-850-900-950-1000 | ||
1250 | 850-900-950-1000-1050-1100-1150-1200-1250 | |||
Action tolerance | ±20% |
010203040506