Leave Your Message
WLM7DC-630A-3300 3P  WLM7DC Series 2Poles  3Poles  Photovoltaic solar type DC circuit breaker OEM 250vdc/500vdc/750VDC/1000VDC/1500VDC 500A 3 Poles  Photovoltaic DC circuit breaker solar mccb

WLM7DC

WLM7DC-630A-3300 3P WLM7DC Series 2Poles 3Poles Photovoltaic solar type DC circuit breaker OEM 250vdc/500vdc/750VDC/1000VDC/1500VDC 500A 3 Poles Photovoltaic DC circuit breaker solar mccb

Rated Current : 630A

Number Of Poles : 2P/3P

Rated Working Voltage : 800V

    MCCB Highlights

    DC MCCB based Switch Disconnectors WLM7DC are used as a main switch in all kinds of DC applications. Thanks to theirs polarity independence can be used also for PV. They serve there as a main disconnector of DC side of the power plant in combiner or array boxes. These switch disconnectors have same size and design as standard WLM7DC MCCBs. Therefore is there possibility to use fully compatible range of external and internal accessories including extended rotary handles, auxiliary contacts, tripping units, motor operators and terminal covers.


    Main performance index of WLM7DC  series circuit breaker

    WLM7DC Moulded Case Circuit Breaker
    630
    Rated operating current In (A),40℃
    400-500-630
    Rated insulation voltage Ui (V) 1500
    Rated impulse withstand voltage (kV) 12
    Rated operational voltage Ue(V),AC 50/60Hz
    110/250/500/750/1000/1200/1500
    Breaking capacity code - M H
    Number of poles 2P
    -
    3P -
    DC250V - 25 50
    DC500V - 25 50
    Rated ultimate
    short-circuit breaking
    capacity Icu(kA)
    DC750V - 15 35
    DC1000V - 15(3P30) 35(3P30)
    DC1250V - - -
    DC1500V - 10(3P25) 25
    Rated service breaking
    capacity Ics(kA)
    DC250V - 25 50
    DC500V - 25 50
    DC750V - 15 35
    DC1000V - 15(3P30) 35
    DC1250V - - -
    DC1500V - 10(3P25) 25
    Standard IEC/EN 60947-2
    Utilization category A
    Ambient temperature -40℃ ~+70 ℃
    Safety of insulation
    Arcing distance 0
    Mechanical life
    (CO recycle)
    Maintenance free 20000
    Electrical life
    (CO recycle)
    Maintenance free 2000(DC1500V is :1000times)
    Release units
    Distribution protection
    TM
    Mounting and connection
    Fixed
    Front connection
    Rear connection
    Plug-in
    Front connection
    Rear connection
    Draw-out
    Front connection -
    Rear connection -
    DIN rail
    Front connection -
    Dimension
    Dimension (mm)
    W×H×D
    Width 130/182
    Height 270
    Depth 154.5
    Weight
    Weight(kg)/Fixed
    2P 2
    3P 8.3
    4P -

    Overall and installation dimensions of circuit breaker


    400630800qzw

    MCCB Production Line Real Showing

    Leave Your Message