Productos | Modelo | Actual | polacos | Descripción |
interruptor magnetotérmico de 6 kA | JCB3-80M | 1A--80A | 1P, 2P, 3P, 4P | Curva B, C, D |
JCB3-40M | 1A--40A | Curva B, C, D |
JCB1-125 | 63A-125A | Curva C, D |
interruptor magnetotérmico de 10 kA | JCB3-80H | 1A--80A | Curva B, C, D |
JCBH-125 | 63A-125A | Curva C, D |
interruptor magnetotérmico de 15 kA | JC3BE | 1A-80A | Curva B, C, D |
MCB CC | JCB3-63DC | 6A-63A | 250 V, 500 V, 750 V, 1000 V |
JCB1-125DC | 63A-125A | 250 V, 500 V, 750 V, 1000 V |
Aislador | JCH2-125 | 16A-125A | / |
JCMS100 | 16A-100A | / |
JCMS125 | 16A-125A | / |
RCD | JC3RH | 25A-100A | 2P, 4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S |
JC3RH-S | 25A-100A | 2P, 4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S |
JC3RH-B | 25A-100A | 2P, 4P | 30 mA, 100 mA, 300 mA | Tipo B |
RCBO | Electrónico | JCB2LE-40M | 2A-40A | 1P+N | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
JC3LFED | 2A-40A | 2P, 4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
JCB2LE-80M 2P | 6A-80A | 1P, 2P, 3P, 4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
JCB2LE-80M 4P | 6A-80A | 1P, 2P, 3P, 4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
JCB1LE-125 | 63A-125A | 2P, 4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
Electromagnético | JCB3LM-80 | 6A-80A | 2P/4P | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
JCR2-63 | 6A-63A | 1P+N | 30 mA, 100 mA, 300.500 mA | Tipo CA, tipo A, A+S | Curva B, curva C |
tipo B | JC3LEB | 6A-63A | 2P, 4P | 30 mA, 100 mA, 300.500 mA | 2do cuadrado, 4to cuadrado | Curva B, curva C |
AFDD | JC3AE | 6A-63A | 1P, 2P | 30 mA, 100 mA | Curva B, curva C |
JC3AF-S | 6A-40A | 1P, 2P | 30 mA, 100 mA | Curva B, curva C |
SPD de CA | JCSD-40 | Voltaje: 275 V. | 1 polo, 2 polos, 1P+N, 3 polos, 4 polos, 3P+N | Tipo 2 | 20kA/40KA |
JCSP-40 | 1 polo, 2 polos, 1P+N, 3 polos, 4 polos, 3P+N |
JCSD-60 | 2 polos, 1P+N, 4 polos, 3P+N | Tipo 2 | 30/60KA |
JCSP-60 | (1000 V 3P) |
JCT1 | 2 polos, 1P+N, 4 polos, 3P+N | Tipo 1 | 12,5kA/50kA (10/350 µs) |
SPD CC | JCSPV | (por debajo de 800V2P, por encima de 1000V3P) | Tipo 2, 500 V CC, 600 V CC, 800 V CC, 1000 V CC, 1200 V CC, 1500 V CC |
Contactor de CA | CJX2 | 3P, 4P | 9A, 12A, 18A, 25A, 32A, 40A, 50A, 65A, 80A, 95A |
Caja de distribución | Metal | MS, RCD, RCD doble | 4 vías, 6 vías, 8 vías, 10 vías, 12 vías, 14 vías, 16 vías, 18 vías, 20 vías, 22 vías, 28 vías, 36 vías |
El plastico | 4 vías, 8 vías, 12 vías, 18 vías, 26 vías, 36 vías, 54 vías |