The most important features
● Highly compact design - only 1 module, width 18mm, 1P+N is located in one module, which can effectively utilize the space of distribution board and distribution board.
● Provide reliable short circuit and overload protection to protect electrical systems and equipment from potential damage.
● The rated switching capacity in accordance with IEC/EN 60898-1 is 6 kA, ensuring safe interruption of fault currents under specified conditions.
● Supports rated current up to 40A to meet a wide range of electrical load requirements for various applications.
● Trip characteristics B and C are available, allowing customization to specific application requirements and load types.
● The mechanical life span reaches 20,000 times and the electrical life span reaches 4,000 times, ensuring long-term durability and reliability.
● Equipped with contact position indicator, green means "OFF", red means "ON", the status indication is clear at a glance.
● Meets the insulation coordination requirements, the safety distance between contacts is ≥4mm, and complies with safety standards.
● It can be flexibly installed on the top or bottom busbar as needed, providing installation versatility.
● Compatible with front-out power supply bus/DPN bus, providing compatibility with different types of bus systems.
● It has a tightening torque of 2.5N to ensure a firm and reliable connection during installation.
● Can be installed quickly and easily on 35mm DIN rail (IEC60715), simplifying the installation process and saving time.
● Comply with IEC 60898-1 standard to ensure that circuit protection devices comply with international safety and performance standards.
Technical Data
●Standards: Comply with IEC 60898-1 and EN 60898-1 standards to ensure compliance with international safety and performance requirements.
● Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, multiple options to meet different electrical load needs.
● Rated working voltage: Supports multiple rated working voltages such as 110V, 230V, 240V, etc., providing flexibility for different electrical systems and applications.
● Rated breaking capacity: It has a high rated breaking capacity of 6kA, ensuring that fault current can be safely broken under specified conditions.
● Insulation voltage: rated 500V, ensuring sufficient insulation protection of the circuit breaker.
● Rated impulse withstand voltage (1.2/50): It can withstand 4kV rated impulse voltage and provides surge and transient voltage protection.
● Thermomagnetic release characteristics: There are three options: B curve, C curve, and D curve, which can be customized according to specific application requirements.
● Mechanical life: The mechanical life is up to 20,000 operating cycles, ensuring long-term durability and reliability under various working conditions.
● Electrical life: The electrical life is 4000 operating cycles, providing consistent performance over an extended period of time.
● Protection level: IP20, which means it can protect solid objects larger than 12mm, and can protect fingers or similar objects.
● Ambient temperature: Suitable to operate within the ambient temperature range of -5°C to +40°C, with the daily average temperature not exceeding 35°C, ensuring reliable performance under various environmental conditions.
● Terminal connection method: Supports cable and pin busbar connections, with flexible installation and connection methods.
● Installation: It can be easily installed on DIN rail EN 60715 (35mm) using the quick clamp device, simplifying the installation process and saving time.
● Recommended torque: The recommended torque is 2.5Nm to ensure a firm and reliable connection during installation.
Technical Data
Technical data:
●Standards: Comply with IEC 60898-1 and EN 60898-1 standards to ensure compliance with international safety and performance requirements and provide quality and reliability assurance.
● Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, multiple options to meet the electrical load needs of various occasions. app.
● Rated working voltage: Supports multiple rated working voltages such as 110V, 230V, 240V, etc., providing flexibility for different electrical systems and applications, ensuring compatibility with multiple voltage requirements.
● Rated breaking capacity: It has a high rated breaking capacity of 6kA, ensuring the ability to safely break fault currents under specified conditions and providing reliable protection for electrical systems and equipment.
● Insulation voltage: rated 500V, ensuring sufficient insulation protection of the circuit breaker, which is conducive to the safety and reliability of electrical installation.
● Rated impulse withstand voltage (1.2/50): It can withstand a rated impulse voltage of 4kV, provides surge and transient voltage protection, and ensures the durability and robustness of the circuit breaker.
● Thermal magnetic tripper characteristics: There are B curve, C curve, and D curve to choose from, which can be customized according to specific application requirements to ensure accurate and reliable tripping characteristics.
● Mechanical life: The mechanical life is up to 20,000 operating cycles, ensuring long-term durability and reliability under various working conditions, which is beneficial to the service life of the circuit breaker.
● Electrical life: The electrical life is up to 4,000 times, and the long-term performance is stable, ensuring the reliability and service life of the circuit breaker.
● Protection level: IP20, which means it can protect solid objects larger than 12mm, and can protect fingers or similar objects to ensure the high safety of the circuit breaker.
● Ambient temperature: Suitable to operate within the ambient temperature range of -5°C to +40°C, with the daily average temperature not exceeding 35°C, ensuring reliable performance under various environmental conditions and providing versatility for installation under different settings.
● Contact position indicator: It has a clear and intuitive indicator, green means "OFF" and red means "ON", providing intuitive status indication to increase convenience and safety.
● Terminal connection method: Supports cable and pin busbar connections, flexible installation and connection methods, and compatible with various wiring methods.
● Installation: Conveniently installed on DIN rail EN 60715 (35mm) via quick clamp device, simplifying the installation process and saving time, and ensuring a safe and reliable installation solution.
● Recommended torque: The recommended torque is 2.5Nm to ensure a firm and reliable connection during installation, which is beneficial to the overall safety and performance of the circuit breaker.
When selecting the right type of circuit breaker for a specific application, several key criteria must be considered to ensure optimal performance and safety. The following three criteria must be considered:
1) Current limiting level (=selectivity level)
MCBs are classified into current-limiting (selective) Level 1, Level 2 and Level 3 based on off-time under short circuit conditions. These categories determine the circuit breaker's ability to limit the magnitude of short-circuit current and provide selectivity in the distribution system. Category 1 offers the highest selectivity, while Category 3 offers the lowest selectivity. Understanding selectivity levels is critical to ensuring proper coordination and protection within electrical installations.
2) Rated current
The rated current of a circuit breaker indicates the current value that the MCB can permanently withstand at an ambient temperature of 30°C, especially in residential and commercial applications. It is important to select a circuit breaker with an ampere rating that matches the specific electrical load requirements of the application to ensure reliable and safe operation.
3) Trip characteristics
Circuit breakers with Type B and Type C trip characteristics are the most common types as they are the standard for residential and commercial applications. The tripping characteristics determine the circuit breaker's response to overcurrent. Characteristic B is suitable for circuits with mainly resistive loads, while characteristic C is suitable for circuits with mixed resistive loads and inductive loads. Understanding the tripping characteristics is critical to ensuring that a circuit breaker provides effective overload and short-circuit protection in a specific application.
By carefully considering these criteria, the most appropriate circuit breaker can be selected for a specific application, ensuring optimal performance, safety and protection of electrical systems and equipment.