Leave Your Message
JCB2-40M Miniature Circuit Breaker 6kA 1P+N

MCB

JCB2-40M Miniature Circuit Breaker 6kA 1P+N

JCB2-40 Miniature Circuit Breakers for use in domestic installations, as well as commercial and industrial distribution systems.
Exclusive design for your safety!
Short circuit and overload protection
Breaking capacity up to 6kA
With contact indicator
1P+N in one module
Can be made from 1A to 40A
B , C or D curve
Comply with IEC 60898-1

    Introduction

    JCB2-40M is a low voltage miniature circuit breaker (MCB). It is a 1P+N circuit breaker with 1 module 18mm width.

    JCB2-40M DPN circuit breaker is designed to offer enhanced protection by preventing, protecting people and equipment from electrical threats. They provide protection against overload current and short circuit protection and Switch function.Its fast closing mechanism and high performance limitation improve its service life.

    JCB2-40M miniature circuit breaker (MCB) is a protective device that’s equipped with both a thermal and an electromagnetic release. The former responds in the event of an overload, while the latter offers protection against short circuits.

    JCB2-40M short circuit breaking capacity is up ot 6kA at 230V/240V ac conforming to IEC60897-1 & EN 60898-1. They comply with with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2.

    JCB2-40 circuit breaker has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles.

    JCB2-40M circuit breaker is compatible with prong-type supply busbar/ DPN pin type Busbar. They are 35mm din rail mounted.

    JCB2-40M circuit breaker has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 70°C. The operating frequency is 50Hz or 60Hz. The Ui rated insulation voltage is 500VAC.

    The Uimp rated impulse withstand voltage is 4kV.

    JCB2-40M circuit breaker is available with tripping characteristics B, C and D, is equipped with a red-green contact-position indicator for indicating the device state.

    JCB2-40M circuit breaker is Used for overload and short circuit protection of lighting, power distribution lines and equipment in office buildings, residences and similar buildings, and can also be used for infrequent on-off operations and conversion of lines. Mainly used in various places such as industry, commerce, high-rise and civil residence.

    JCB2-40M circuit breaker is intended for the protection of circuits against overloads and short circuits. Upstream and downstream bi-stable DIN rail latches facilitate the mounting of the circuit breakers onto the DIN rail. Theses devices can be locked in the off position by the use of the integrated locking facility on the toggle. This lock allows you to insert a 2.5-3.5mm cable tie where you can fit a warning card if necessary and allows a safer working environment for all personnel.

    As with all of our products, this product comes with a 5 Year Warranty. This is so that you can have peace of mind knowing that if a fault arises within a five year period, we will cover the cost of replacing the product and it’s installation by an authorised electrician. In other words, we have got your back.

    Product Description

    1-32ic8

    The most important features

     ● Highly compact design - only 1 module, width 18mm, 1P+N is located in one module, which can effectively utilize the space of distribution board and distribution board.
     ● Provide reliable short circuit and overload protection to protect electrical systems and equipment from potential damage.
     ● The rated switching capacity in accordance with IEC/EN 60898-1 is 6 kA, ensuring safe interruption of fault currents under specified conditions.
     ● Supports rated current up to 40A to meet a wide range of electrical load requirements for various applications.
     ● Trip characteristics B and C are available, allowing customization to specific application requirements and load types.
     ● The mechanical life span reaches 20,000 times and the electrical life span reaches 4,000 times, ensuring long-term durability and reliability.
     ● Equipped with contact position indicator, green means "OFF", red means "ON", the status indication is clear at a glance.
     ● Meets the insulation coordination requirements, the safety distance between contacts is ≥4mm, and complies with safety standards.
     ● It can be flexibly installed on the top or bottom busbar as needed, providing installation versatility.
     ● Compatible with front-out power supply bus/DPN bus, providing compatibility with different types of bus systems.
     ● It has a tightening torque of 2.5N to ensure a firm and reliable connection during installation.
     ● Can be installed quickly and easily on 35mm DIN rail (IEC60715), simplifying the installation process and saving time.
     ● Comply with IEC 60898-1 standard to ensure that circuit protection devices comply with international safety and performance standards.

     

    Technical Data

     ●Standards: Comply with IEC 60898-1 and EN 60898-1 standards to ensure compliance with international safety and performance requirements.
     ● Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, multiple options to meet different electrical load needs.
     ● Rated working voltage: Supports multiple rated working voltages such as 110V, 230V, 240V, etc., providing flexibility for different electrical systems and applications.
     ● Rated breaking capacity: It has a high rated breaking capacity of 6kA, ensuring that fault current can be safely broken under specified conditions.
     ● Insulation voltage: rated 500V, ensuring sufficient insulation protection of the circuit breaker.
     ● Rated impulse withstand voltage (1.2/50): It can withstand 4kV rated impulse voltage and provides surge and transient voltage protection.
     ● Thermomagnetic release characteristics: There are three options: B curve, C curve, and D curve, which can be customized according to specific application requirements.
     ● Mechanical life: The mechanical life is up to 20,000 operating cycles, ensuring long-term durability and reliability under various working conditions.
     ● Electrical life: The electrical life is 4000 operating cycles, providing consistent performance over an extended period of time.
     ● Protection level: IP20, which means it can protect solid objects larger than 12mm, and can protect fingers or similar objects.
     ● Ambient temperature: Suitable to operate within the ambient temperature range of -5°C to +40°C, with the daily average temperature not exceeding 35°C, ensuring reliable performance under various environmental conditions.
     ● Terminal connection method: Supports cable and pin busbar connections, with flexible installation and connection methods.
     ● Installation: It can be easily installed on DIN rail EN 60715 (35mm) using the quick clamp device, simplifying the installation process and saving time.
     ● Recommended torque: The recommended torque is 2.5Nm to ensure a firm and reliable connection during installation.

     

    Technical Data

     Technical data:
     ●Standards: Comply with IEC 60898-1 and EN 60898-1 standards to ensure compliance with international safety and performance requirements and provide quality and reliability assurance.
     ● Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, multiple options to meet the electrical load needs of various occasions. app.
     ● Rated working voltage: Supports multiple rated working voltages such as 110V, 230V, 240V, etc., providing flexibility for different electrical systems and applications, ensuring compatibility with multiple voltage requirements.
     ● Rated breaking capacity: It has a high rated breaking capacity of 6kA, ensuring the ability to safely break fault currents under specified conditions and providing reliable protection for electrical systems and equipment.
     ● Insulation voltage: rated 500V, ensuring sufficient insulation protection of the circuit breaker, which is conducive to the safety and reliability of electrical installation.
     ● Rated impulse withstand voltage (1.2/50): It can withstand a rated impulse voltage of 4kV, provides surge and transient voltage protection, and ensures the durability and robustness of the circuit breaker.
     ● Thermal magnetic tripper characteristics: There are B curve, C curve, and D curve to choose from, which can be customized according to specific application requirements to ensure accurate and reliable tripping characteristics.
     ● Mechanical life: The mechanical life is up to 20,000 operating cycles, ensuring long-term durability and reliability under various working conditions, which is beneficial to the service life of the circuit breaker.
     ● Electrical life: The electrical life is up to 4,000 times, and the long-term performance is stable, ensuring the reliability and service life of the circuit breaker.
     ● Protection level: IP20, which means it can protect solid objects larger than 12mm, and can protect fingers or similar objects to ensure the high safety of the circuit breaker.
     ● Ambient temperature: Suitable to operate within the ambient temperature range of -5°C to +40°C, with the daily average temperature not exceeding 35°C, ensuring reliable performance under various environmental conditions and providing versatility for installation under different settings.
     ● Contact position indicator: It has a clear and intuitive indicator, green means "OFF" and red means "ON", providing intuitive status indication to increase convenience and safety.
     ● Terminal connection method: Supports cable and pin busbar connections, flexible installation and connection methods, and compatible with various wiring methods.
     ● Installation: Conveniently installed on DIN rail EN 60715 (35mm) via quick clamp device, simplifying the installation process and saving time, and ensuring a safe and reliable installation solution.
     ● Recommended torque: The recommended torque is 2.5Nm to ensure a firm and reliable connection during installation, which is beneficial to the overall safety and performance of the circuit breaker.

    Standard IEC/EN 60898-1  IEC/EN 60947-2

    Electrical features

    Rated current In (A) 1, 2, 3, 4, 6, 10, 16,
    20, 25, 32, 40, 50, 63,80
    Poles 1P, 1P+N, 2P, 3P, 3P+N, 4P 1P, 2P, 3P, 4P
    Rated voltage Ue(V) 230/400~240/415
    Insulation voltage Ui (V) 500
    Rated frequency 50/60Hz
    Rated breaking capacity 10 kA
    Energy limiting class 3  
    Rated impulse withstand voltage(1.2/50) Uimp (V) 4000
    Dielectric test voltage at ind. Freq. for 1 min (kV) 2
    Pollution degree 2
    Power loss per pole Rated current (A)
    1, 2, 3, 4, 5, 6, 10,13, 16, 20, 25, 32,40, 50, 63, 80
    Thermo-magnetic release characteristic B, C, D 8-12In, 9.6-14.4In

    Mechanical features

    Electrical life 4, 000
    Mechanical life 20, 000
    Contact position indicator Yes
    Protection degree IP20
    Reference temperature for setting of thermal element(℃) 30
    Ambient temperature (with daily average ≤35℃) -5...+40
    Storage temperation (℃) -35...+70
    Installation Terminal connection type Cable/U-type busbar/Pin-type busbar
    Terminal size top/bottom for cable 25mm2  / 18-4 AWG
    Terminal size top/bottom for Busbar 10mm2  / 18-8 AWG
    Tightening torque 2.5 N*m  /  22 In-Ibs.
    Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
    Connection From top and bottom

    Combination
    with
    accessories

    Auxiliary contact Yes
    Shunt release Yes
    Under voltage release Yes
    Alarm contact Yes
    JCB2-40-CURVEaexdrawings2di

     When selecting the right type of circuit breaker for a specific application, several key criteria must be considered to ensure optimal performance and safety. The following three criteria must be considered:
     1) Current limiting level (=selectivity level)
     MCBs are classified into current-limiting (selective) Level 1, Level 2 and Level 3 based on off-time under short circuit conditions. These categories determine the circuit breaker's ability to limit the magnitude of short-circuit current and provide selectivity in the distribution system.  Category 1 offers the highest selectivity, while Category 3 offers the lowest selectivity. Understanding selectivity levels is critical to ensuring proper coordination and protection within electrical installations.
    2) Rated current
     The rated current of a circuit breaker indicates the current value that the MCB can permanently withstand at an ambient temperature of 30°C, especially in residential and commercial applications. It is important to select a circuit breaker with an ampere rating that matches the specific electrical load requirements of the application to ensure reliable and safe operation.
    3) Trip characteristics
     Circuit breakers with Type B and Type C trip characteristics are the most common types as they are the standard for residential and commercial applications. The tripping characteristics determine the circuit breaker's response to overcurrent. Characteristic B is suitable for circuits with mainly resistive loads, while characteristic C is suitable for circuits with mixed resistive loads and inductive loads. Understanding the tripping characteristics is critical to ensuring that a circuit breaker provides effective overload and short-circuit protection in a specific application.
     By carefully considering these criteria, the most appropriate circuit breaker can be selected for a specific application, ensuring optimal performance, safety and protection of electrical systems and equipment.