JCSD Alarm Auxiliary Contact
Introduction
This JCSD electrical auxiliary is a modular fault contact used as remote indication of tripping upon a fault of the associated device. The In rated current is from 2mA to 100mA at 24VAC to 240VAC with operating frequency of 50Hz to 60Hz , and from 2mA to 100mA at 24VDC to 220VDC. It has 1 position switch with contacts type 1 C/O. It has 1 position switch with contacts type 1 C/O. It is intended for new or renovated installation in small commercial, buildings, critical buildings, healthcare, industry, data center and infrastructures. The SD is either used for device short name or compatibility code. The mechanical indicator is provided within the product for local signalling. It has a screw clamp terminal connection at bottom. The connection allows rigid copper cable with a cable cross section of 0.5mm² to 2.5mm². It has a screw clamp terminal connection at bottom. The connection allows flexible copper cables (2 cables) with a cable cross section of 1.5mm². It has a screw clamp terminal connection at bottom. The connection allows flexible with ferrule copper cables (2 cables) with a cable cross section of 1.5mm². The Ui rated insulation voltage is up to 500V. It has a Uimp rated impulse withstand voltage of 4kV. It can be mounted on DIN rail for modular installation. The width in 9mm pitches is 1. The pollution degree is 3. The level of tropicalisation is treatment 2. The wire stripping length is 9mm. The tightening torque of connection is 1N.m (bottom) for PZ1 screwdriver type. The IP degree of protection is IP20. The operating temperature is from -25°C to +70°C. The storage temperature is from -40°C to +85°C. This product complies with EN/IEC 60947-5-1, EN/IEC 60947-5-4 standards.
Product Description
Standard | IEC61009-1 , EN61009-1 | ||
Electrical features | Rated value | UN(V) | In (A) |
AC415 50/60Hz | 3 | ||
AC240 50/60Hz | 6 | ||
DC130 | 1 | ||
DC48 | 2 | ||
DC24 | 6 | ||
Configurations | 1 N/O+1N/C | ||
Rated impulse withstand voltage(1.2/50) Uimp (V) | 4000 | ||
Poles | 1 Pole (9mm Width) | ||
Insulation voltage Ui (V) | 500 | ||
Dielectric TEST voltage at ind.Freq.for 1 min (kV) | 2 | ||
Pollution degree | 2 | ||
Mechanical features | Electrical life | 6050 | |
Mechanical life | 10000 | ||
Protection degree | IP20 | ||
Ambient temperature (with daily average ≤35℃) | -5...+40 | ||
Storage temperation (℃) | -25...+70 | ||
Installation | Terminal connection type | Cable | |
Terminal size top/bottom for cable | 2.5mm2 / 18-14 AWG | ||
Tightening torque | 0.8 N*m / 7 In-Ibs. | ||